    ARMSTRONG FL/SL C/D

    Floor Hardeners & Epoxy Floors

    ESD Protection
    Conductive/Dissipative
    Seamless
    Epoxy Base
    Floor Hardeners & Epoxy Floors

    ARMSTRONG FL/SL C/D

    Two-component epoxy floor topping that gives ESD protection in static conductive or dissipative grades, with a seamless finish for electronics and data centre floors.

    • Anti static server room floor
    • ESD floor for electronics
    • Operating theatre static control
    • Explosive storage flooring

    Epoxy based Static Conductive / Dissipative seamless floor toppings. Specialist two-component epoxy flooring system providing ESD (electrostatic discharge) protection. Essential for electronic manufacturing, data centres, operating theatres, and areas requiring strict static control.

    Share

    Specifications

    TypeEpoxy Static Conductive / Dissipative Floor Topping
    ComponentsTwo Component Epoxy
    PropertiesESD — Static Conductive or Dissipative
    FinishSeamless
    ApplicationsElectronic & ESD sensitive environments
    ThicknessAs specified per project requirements

    Figures are controlled laboratory results. Actual site performance varies with substrate, temperature, humidity, application method and workmanship — please confirm the current product datasheet before specification.

    Where to use ARMSTRONG FL/SL C/D: ESD flooring for static control

    ARMSTRONG FL/SL C/D is an ESD flooring system, a two-component epoxy topping made in static conductive or dissipative versions. It goes over a conductive primer coat and a copper tape earthing grid, and is applied by squeegee and roller. The result is an anti static epoxy floor with a seamless finish.

    • Electronic Manufacturing Facilities

      ESD protection for floors in electronic manufacturing.

    • Data Centres & Server Rooms

      Static control flooring over a copper tape earthing grid.

    • Operating Theatres & Cleanrooms

      Seamless epoxy topping for areas requiring strict static control.

    • Explosive Storage Areas

      Conductive or dissipative grade, with resistance values verified on site.

    • Aviation Maintenance Hangars

      Applied by squeegee and roller in the specified thickness.

    • Pharmaceutical Facilities

      Laid over a conductive primer on shot blasted concrete.

    For an anti static floor for a server room, resistance must be verified after application: conductive below 1 MΩ, dissipative 1 MΩ to 1 GΩ. That is the difference between a conductive floor coating and a dissipative one. Thickness is as specified per project. Prepare the concrete to a CSP 3–4 profile, and allow a full cure of 7 days before heavy traffic.

    Armstrong Chemicals supplies ARMSTRONG FL/SL C/D to sites across Telangana, Andhra Pradesh, Karnataka, Kerala and Tamil Nadu, including Hyderabad, Vijayawada, Bengaluru, Kochi and Chennai.

    Why ARMSTRONG FL/SL C/D works

    • Copper earthing grid

      The copper tape earthing grid conducts static charges safely to ground, which the ESD protection depends on.

    • Conductive or dissipative

      Conductive floors below 1 MΩ discharge static rapidly, while dissipative floors from 1 MΩ to 1 GΩ discharge it in a slower, controlled way.

    • Seamless epoxy topping

      The two-component epoxy forms a seamless finish, one of the stated properties of the system.

    How to Use

    1

    Prepare concrete substrate to CSP 3–4 profile by shot blasting or grinding

    2

    Repair cracks and defects with epoxy repair mortar

    3

    Apply conductive primer coat to establish earthing network

    4

    Install copper tape earthing grid as per design

    5

    Apply ARMSTRONG FL/SL C/D in specified thickness by squeegee and roller

    6

    Verify resistance values meet specification (conductive <1MΩ, dissipative 1MΩ–1GΩ)

    7

    Allow full cure of 7 days before heavy traffic

    Applicable Areas

    Electronic Manufacturing FacilitiesData Centres & Server RoomsOperating Theatres & CleanroomsExplosive Storage AreasAviation Maintenance HangarsPharmaceutical Facilities

    Coverage Calculator

    Coverage estimation is not applicable for this product. Please contact our team for application guidance.

    Product Brochure

    PDF

    Download Technical Datasheet

    Full specifications, application systems, layering guides, and coverage tables.