    1. Chip deteriorated and loose material and clean rust from exposed bars with a wire brush.
    2. Add steel where needed and coat exposed bars with ALSTRONG AC; let it dry.
    3. Dampen the surface thoroughly, with no water standing.
    4. Apply a bond coat of ROOFBOND SBR 401 mixed with cement.
    5. Lay 1:4 cement mortar with CONPROOF 500 at 500 ml per 50 kg of cement: 20 mm first coat and 10 mm finishing coat. Over a membrane, lay about 20 mm, up to 300 mm on the walls.
    6. Cure for at least 7 days.

    Mix CONPROOF 500 into 3 to 5 litres of water first, then add to the mix. Keep the water low.

    The micronised compound lines the capillaries with water-repellent particles, so the plaster resists water while staying strong and bonding well.